To correct this situation, change 'arbitrary' to 'known' in Pro. In case you entered known coordinates for your base station, but left the Base Coord field 'unknown' by accident. Similarly to the xfm setting of the first file, it is the setting in the first file which determines whether 'known' or 'unknown' initial coordinates are used in a Pro.
This should get your job within a few meters. If you do have known coordinates for your base, use 'known' setting - and you don't need to do a calibration.īut visit a known point as a check. You can now enter completely arbitrary coordinates.īut you must visit a known point with the rover and perform a calibration on the data- collector to get to your desired coordinate system. If you do not have known coordinates for the GPS base station, use 'unknown' setting. 6, you'll get an error message if following files are recorded on other zones or did not use an. Link project determines the coordinate system used in that project. The first file you import into a new Pro. SDR datalogger in a GPS RTK survey, is not present on the PC.įor Australia, typically the AUST0. You'll see this error message when the transformation file (*. Notepad, not MSWord) at the data- file, to see whether the import format you selected actually matches the contents of the ascii file. Once you have a new cable, make sure not to squash the cable by inserting the SDR3. Total Station, the cable attached to the SDR3. If you have (intermittent) communication problems between the SDR3. The same settings apply if you're using an external SCR2 card reader. These instruments should be set 'On Line' in the Menu/Card/Comms menu and will receive a *. Set File Type in the left hand screen to *. 32 speed in instrument !) to communicate. Cii and other C series with built- in Sokkia data cards will use the ' SCR2' device (set to 9. Not occupied by Activesync, for instance. Leave Xon/Xoff unchecked and handshake 'none' for now.
PC and in the instrument?Ĭheck the speed (baud rate) but also the parity, data bits, stop bits. If your Total Station or SDR data- logger is sending the job (records are counting) but the PC is still displaying 'waiting to receive' check the following. You'll need to set the PC ready to receive and then 'send' the job from the Total Station. For most Sokkia Total Stations use the SDR3.
Se puede usar tambien para equipo Sokkia en Windows Vista y Windows 7 Sokkia Prolink y Sokkia Link Prolink version 1. Sokkia prolink intrucciones de uso para descarga de DATOS. Sokkia Prolink 1.15 Software Free Download? Sokkia Link Program Free Download? Find answers researching ebooks, papers or essays. Read related documents and downloads about Sokkia Prolink Software Free Download. Prolink 1.15 Prolink version 1.15, completa y sin llave. TOPCON GOWIN EManual de instrucciones en espa. To transfer a file from a Sokkia Total Station you can use the 'receive' function in Pro. When re- opening a project, the co- ordinate order reverts to Northing, Easting, even if you set the default to Easting, Northing. LINK is a Shareware software in the category System Utilities developed by Prolink. 96 users of Software Informer have this software installed on their The most commonly used version of Prolink is 1.
Download Realtek High Definition Audio Driver 6.
Now we'll see how to download data to the computer, using one of the guides that made by one of my technicians. Reducing RTK data in Prolink: Antenna height of second and subsequent base stations in the same file are ignored - so if the second base station has a different antenna height, you'll see incorrect elevations for all points observed using that second base station.
Sin and Cos functions in customised exports don't work. Sometimes a change of target height is skipped in the reduction process, leading to incorrect heights for all points till the next target height change. If you've downloaded an unreduced file for archiving purposes, you may send it back to the controller to be reduced or to continue field work. GPS RTK only) Prolink does not use a geoid model, so be aware you may find height differences between the results from the data- collector and the reduction from Prolink. Each project is stored in a directory of its own. Link requires Administrator rights when using projects.